설계 · 강재

단면의 설계 압축 저항 Nc,Rd

  • 유형: 저항
  • 버전 1
  • 2026. 11. 9.에 검토됨

1, 2 또는 3급 단면의 설계 압축 저항: Nc,Rd = A · fy / γM0.

Nc,Rd=A⋅fyγM0\displaystyle N_{\mathrm{c},\mathrm{Rd}} = \frac{A \cdot f_{y}}{\gamma_{\mathrm{M0}}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fyNc,Rd

Formula and quantities

SymbolNameUnitNote
A\displaystyle A단면적m²
fy\displaystyle f_{y}항복 강도N/mm²
γM0\displaystyle \gamma_{\mathrm{M0}}단면 저항에 대한 부분계수–
Nc,Rd\displaystyle N_{\mathrm{c},\mathrm{Rd}}설계 압축 저항kNResult

예제

A\displaystyle A = 0.01491 m² · fy\displaystyle f_{y} = 355 N/mm² · γM0\displaystyle \gamma_{\mathrm{M0}} = 1

Nc,Rd\displaystyle N_{\mathrm{c},\mathrm{Rd}} = 5,293.05 kN · Source: EN 1993-1-1:2005 식 (6.10)

Scope and standard

EN 1993-1-1, 6.2.4절에 따른 1, 2, 3급 단면.

Standard
EN 1993-1-1:2005, 6.2.4 (2) 절, 식 (6.10)
Result
Nc,Rd\displaystyle N_{\mathrm{c},\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Nc,Rd\displaystyle N_{\mathrm{c},\mathrm{Rd}} = 5,293.05 kN= (0.01491 m²) · (355 N/mm²) / 1

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

설계 › 강재에서 검색이 시작됩니다.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.