設計 · 鋼構造
断面の設計圧縮耐力 Nc,Rd
クラス1、2または3の断面の設計圧縮耐力:Nc,Rd = A · fy / γM0。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 断面積 | m² | ||
| 降伏強度 | N/mm² | ||
| 断面耐力に対する部分係数 | – | ||
| 設計圧縮耐力 | kN | Result |
例題
= 0.01491 m² · = 355 N/mm² · = 1
= 5,293.05 kN · Source: EN 1993-1-1:2005 式 (6.10)
Scope and standard
EN 1993-1-1 6.2.4項によるクラス1、2および3の断面。
- Standard
- EN 1993-1-1:2005、6.2.4 (2)項、式 (6.10)
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.