설계 · 알루미늄

설계 인장내력 Nt,Rd

  • 유형: 저항
  • 버전 1
  • 2026. 11. 13.에 검토됨

총단면 항복과 순단면 파단 중 작은 값으로 취하는 알루미늄 인장부재의 지배 설계 내력: Nt,Rd = min(No,Rd, Nu,Rd).

Nt,Rd=min(No,Rd,Nu,Rd)\displaystyle N_{t,\mathrm{Rd}} = min(N_{o,\mathrm{Rd}}, N_{u,\mathrm{Rd}})
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
No,Rd\displaystyle N_{o,\mathrm{Rd}}총단면의 설계 소성 인장내력kN
Nu,Rd\displaystyle N_{u,\mathrm{Rd}}순단면의 설계 극한 인장내력kN
Nt,Rd\displaystyle N_{t,\mathrm{Rd}}설계 인장 저항kNResult

예제

No,Rd\displaystyle N_{o,\mathrm{Rd}} = 590.91 kN · Nu,Rd\displaystyle N_{u,\mathrm{Rd}} = 446.4 kN

Nt,Rd\displaystyle N_{t,\mathrm{Rd}} = 446.4 kN

Standard and source

Result
Nt,Rd\displaystyle N_{t,\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Nt,Rd\displaystyle N_{t,\mathrm{Rd}} = 446.4 kN= min((590.91 kN); (446.4 kN))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

설계 › 알루미늄에서 검색이 시작됩니다.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.