設計 · 接合部

梁フランジおよびウェブの圧縮耐力 Fc,fb,Rd

  • タイプ:耐力
  • バージョン1
  • 2026/11/13にレビュー済み

曲げ接合部における梁フランジおよび隣接ウェブの設計圧縮耐力: Fc,fb,Rd = Mc,Rd / (h - tfb)。

Fc,fb,Rd=Mc,Rd/(h−tfb)\displaystyle F_{\mathrm{c},fb,\mathrm{Rd}} = M_{\mathrm{c},\mathrm{Rd}} / (h - t_{fb})
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzhtfb

Formula and quantities

SymbolNameUnitNote
Mc,Rd\displaystyle M_{\mathrm{c},\mathrm{Rd}}梁断面の設計曲げ耐力Nm
h\displaystyle h梁断面の全高さmm
tfb\displaystyle t_{fb}梁圧縮フランジの板厚mm
Fc,fb,Rd\displaystyle F_{\mathrm{c},fb,\mathrm{Rd}}梁フランジ圧縮耐力kNResult

例題

Mc,Rd\displaystyle M_{\mathrm{c},\mathrm{Rd}} = 223,100 Nm · h\displaystyle h = 300 mm · tfb\displaystyle t_{fb} = 10.7 mm

Fc,fb,Rd\displaystyle F_{\mathrm{c},fb,\mathrm{Rd}} = 771.17 kN

Standard and source

Result
Fc,fb,Rd\displaystyle F_{\mathrm{c},fb,\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Fc,fb,Rd\displaystyle F_{\mathrm{c},fb,\mathrm{Rd}} = 771.172 kN= (223,100 Nm) / ((300 mm) - (10.7 mm))