鋼部材の火災時設計引張耐力 (EN 1993-1-2)
EN 1993-1-2 第4.2.3.1項 式(4.4)による一様温度分布の鋼部材の設計引張耐力: NfitRd = (ky · A · fy) / γMfi.
- EN 1993-1-2:2005
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 温度 Theta における鋼材降伏強度の低減係数 | 1 | ||
| 全断面積 | mm² | ||
| 20°C における鋼材の降伏強度 | N/m² | ||
| 火災時鋼材の部分係数(通常 1.0) | 1 | ||
| 火災時設計引張耐力 | kN | Result |
例題
= 0.78 1 · = 5,000 mm² · = 355,000,000 N/m² · = 1 1
= 1,384.5 kN
Standard and source
- Standard
- EN 1993-1-2:2005
- Result
- in kN