設計 · 鋼構造
火災時座屈不整係数 α (EN 1993-1-2)
EN 1993-1-2 第4.2.3.2項 式(4.6)による火災時鋼柱の曲げ座屈不整係数 alpha: α = 0.65 · √(235 / (fy / MPa)).
- EN 1993-1-2:2005
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 20°C における鋼材の降伏強度 | N/m² | ||
| 火災時座屈不整係数 | 1 | Result |
例題
= 355,000,000 N/m²
= 0.5289 1
Standard and source
- Standard
- EN 1993-1-2:2005
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 鋼構造で開始されます。
Miaknows the formula catalog and asks for what is missing.