設計 · 鋼構造

降伏に対する限界非補剛長さ Lp (AISC)

  • タイプ:特性値
  • バージョン1
  • 2026/11/15にレビュー済み

ANSI/AISC 360-22 第F2節 式F2-5による降伏限界状態の横補剛限界長さ Lp: Lp = 1.76 · ry · √(E / Fy).

Lp=1.76⋅ry⋅EFy\displaystyle L_{p} = 1.76 \cdot r_{y} \cdot \sqrt{\frac{E}{F_{y}}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
ry\displaystyle r_{y}弱軸まわりの断面二次半径mm
E\displaystyle E鋼材の弾性係数N/m²
Fy\displaystyle F_{y}規定最小降伏応力N/m²
Lp\displaystyle L_{p}限界非補剛長さmmResult

例題

ry\displaystyle r_{y} = 50 mm · E\displaystyle E = 200,000,000,000 N/m² · Fy\displaystyle F_{y} = 345,000,000 N/m²

Lp\displaystyle L_{p} = 2,119 mm

Standard and source

Standard
AISC 360-22
Result
Lp\displaystyle L_{p} in m

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Lp\displaystyle L_{p} = 2,118.79 mm= 1.76 · (50 mm) · sqrt((200,000,000,000 N/m²) / (345,000,000 N/m²))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 鋼構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.