設計 · 組積造構造

中空組積造壁の有効厚さ

  • タイプ:特性値
  • バージョン1
  • 2026/11/13にレビュー済み

つなぎ材で緊結された中空壁の有効厚さ:tef = cbrt(ktef · t1³ + t2³)。

tef=ktef⋅t13+t233\displaystyle t_{\mathrm{ef}} = \sqrt[3]{k_{tef} \cdot t_{1}^3 + t_{2}^3}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzt1t2

Formula and quantities

SymbolNameUnitNote
ktef\displaystyle k_{tef}弾性係数比 E_1 / E_2(上限 1.0)–ktef\displaystyle k_{tef} > 0, ≤ 1
t1\displaystyle t_{1}外壁層または非載荷層の厚さmmt1\displaystyle t_{1} > 0
t2\displaystyle t_{2}載荷内壁層の厚さmmt2\displaystyle t_{2} > 0
tef\displaystyle t_{\mathrm{ef}}中空壁の有効厚さmmResult

例題

ktef\displaystyle k_{tef} = 1 · t1\displaystyle t_{1} = 115 mm · t2\displaystyle t_{2} = 175 mm

tef\displaystyle t_{\mathrm{ef}} = 190.197 mm · Source: 手計算

Scope and standard

EN 1996-1-1 条項 5.5.1.3.

Standard
EN 1996-1-1-2005-a1:2012、5.5.1.3項、式 (5.6)
Result
tef\displaystyle t_{\mathrm{ef}} in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
tef\displaystyle t_{\mathrm{ef}} = 190.196 mm= cbrt(1 · (115 mm) ^ 3 + (175 mm) ^ 3)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 組積造構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.