地盤工学 · 土圧
グラウンドアンカー定着長 Lbond
グラウンドアンカーの必要定着長: Lbond = Rak / (π · d · qsk)。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| アンカーの特性引抜抵抗 | kN | ||
| グラウンドアンカー定着体の削孔径 | m | ||
| 定着体と地盤間の特性周面摩擦力 | N/m² | ||
| 必要アンカー定着長 | m | Result |
例題
= 300 kN · = 0.15 m · = 100,000 N/m²
= 6.3662 m · Source: EN 1997-1:2004 第8.5.2条
Scope and standard
EN 1997-1第8.5.2項に基づく注入式グラウンドアンカーの設計。
- Standard
- EN 1997-1:2004、8.5.2項、式 (8.2)
- Result
- in m
Reference to clause and equation, no standard text. The description is written in our own words.