Diseño · Acero

Interacción combinada de fatiga por tensión normal y tangencial (EN 1993-1-9)

  • Tipo: Verificación
  • Versión 1
  • revisado el 24/11/2026

Comprobación combinada de fatiga para rangos simultáneos de tensión normal y tangencial según EN 1993-1-9 cláusula 8(2): ηcomb = ((γFf · ΔσE,2) / (ΔσC / γMf))³ + ((γFf · ΔτE,2) / (ΔτC / γMf))⁵.

ηcomb=(γFf⋅ΔσE,2ΔσC/γMf)3+(γFf⋅ΔτE,2ΔτC/γMf)5\displaystyle \eta_{comb} = \left(\frac{\gamma_{Ff} \cdot \Delta\sigma_{E,2}}{\Delta\sigma_{\mathrm{C}} / \gamma_{Mf}}\right)^3 + \left(\frac{\gamma_{Ff} \cdot \Delta\tau_{E,2}}{\Delta\tau_{\mathrm{C}} / \gamma_{Mf}}\right)^5
  • EN 1993-1-9:2005
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

ΔσCηcombΔσE,2

Formula and quantities

SymbolNameUnitNote
γFf\displaystyle \gamma_{Ff}Coeficiente parcial para rangos de tensión equivalentes de amplitud constante1
ΔσE,2\displaystyle \Delta\sigma_{E,2}Rango de tensión equivalente de daño a 2 millones de ciclosN/m²
ΔσC\displaystyle \Delta\sigma_{\mathrm{C}}Resistencia a fatiga de referencia de la categoría de detalle a 2 millones de ciclosN/m²
ΔτE,2\displaystyle \Delta\tau_{E,2}Rango de tensión tangencial equivalente de daño a 2 millones de ciclosN/m²
ΔτC\displaystyle \Delta\tau_{\mathrm{C}}Resistencia de referencia de la categoría de detalle a cortante a 2 millones de ciclosN/m²
γMf\displaystyle \gamma_{Mf}Coeficiente parcial para la resistencia a fatiga1
ηcomb\displaystyle \eta_{comb}Relación de interacción de fatiga combinada (<= 1,0)1Result

Ejemplo resuelto

γFf\displaystyle \gamma_{Ff} = 1 · ΔσE,2\displaystyle \Delta\sigma_{E,2} = 50.000.000 N/m² · ΔσC\displaystyle \Delta\sigma_{\mathrm{C}} = 80.000.000 N/m² · ΔτE,2\displaystyle \Delta\tau_{E,2} = 45.000.000 N/m² · ΔτC\displaystyle \Delta\tau_{\mathrm{C}} = 80.000.000 N/m² · γMf\displaystyle \gamma_{Mf} = 1,15

ηcomb\displaystyle \eta_{comb} = 0,484574

Standard and source

Standard
EN 1993-1-9:2005
Result
ηcomb\displaystyle \eta_{comb} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ηcomb\displaystyle \eta_{comb} = 0,484574 1= (((1 1) · (50.000.000 N/m²)) / ((80.000.000 N/m²) / (1,15 1)))³ + (((1 1) · (45.000.000 N/m²)) / ((80.000.000 N/m²) / (1,15 1)))⁵

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

La búsqueda comienza en Diseño › Acero.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.