Actions and loads · Traffic loads
Railway Load Model SW/0 total vertical load FSW0 (EN 1991-2)
Total characteristic vertical load of Railway Load Model SW/0 (two uniform load blocks of length a) for continuous railway bridges according to EN 1991-2 Clause 6.3.3: FSW0 = 2 · α · qvk · a.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Classification factor for rail traffic (e.g., 1.0 or 1.21) | 1 | ||
| Characteristic SW/0 line load (133 kN/m) | kN/m | ||
| Length of each uniform load block (15.0 m) | m | ||
| Total vertical load of SW/0 | kN | Result |
Worked examples
Standard alpha=1.0
= 1 · = 133 kN/m · = 15 m
= 3,990 kN
Heavy haul alpha=1.21
= 1.21 · = 133 kN/m · = 15 m
= 4,827.9 kN
Standard and source
- Standard
- EN 1991-2:2003, clause 6.3.3
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.