Design · Timber

Effective number of fasteners in a line nef

  • Type: Coefficient
  • Version 1
  • reviewed on 11/10/2026

Effective number of fasteners in a row parallel to grain according to EN 1995-1-1 8.5.1.1 eq. 8.34: nef = min(n; n⁰.9 · (a1 / (13 · d))⁰.25).

nef=min(n;n0.9⋅(a1/(13⋅d))0.25)\displaystyle n_{\mathrm{ef}} = min(n; n^0.9 \cdot (a_{1} / (13 \cdot d))^0.25)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

dnefna1

Formula and quantities

SymbolNameUnitNote
n\displaystyle nNumber of fasteners in a row1
a1\displaystyle a_{1}Spacing parallel to grainmm
d\displaystyle dFastener diametermm
nef\displaystyle n_{\mathrm{ef}}Effective number of fasteners1Result

Worked example

n\displaystyle n = 4 · a1\displaystyle a_{1} = 80 mm · d\displaystyle d = 12 mm

nef\displaystyle n_{\mathrm{ef}} = 2.947

Standard and source

Result
nef\displaystyle n_{\mathrm{ef}} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
nef\displaystyle n_{\mathrm{ef}} = 2.94676 1= min((4 1); (4 1)⁰.9 · ((80 mm) / (13 · (12 mm)))⁰.25)