Design · Timber

Fastener combined lateral and axial interaction check

  • Type: Verification
  • Version 1
  • reviewed on 11/10/2026

Combined lateral and axial load interaction check for fasteners according to EN 1995-1-1 8.3.3 eq. 8.28: η = (Fv,Ed / Fv,Rd)² + (Fax,Ed / Fax,Rd)² <= 1.0.

η=(Fv,Ed/Fv,Rd)2+(Fax,Ed/Fax,Rd)2\displaystyle \eta = (F_{v,\mathrm{Ed}} / F_{v,\mathrm{Rd}})^2 + (F_{ax,\mathrm{Ed}} / F_{ax,\mathrm{Rd}})^2
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

FvEdFaxEdη

Formula and quantities

SymbolNameUnitNote
Fv,Ed\displaystyle F_{v,\mathrm{Ed}}Design lateral shear loadkN
Fv,Rd\displaystyle F_{v,\mathrm{Rd}}Design lateral load-carrying capacitykN
Fax,Ed\displaystyle F_{ax,\mathrm{Ed}}Design axial tensile loadkN
Fax,Rd\displaystyle F_{ax,\mathrm{Rd}}Design axial withdrawal capacitykN
η\displaystyle \etaCombined interaction ratio1Result

Worked example

Fv,Ed\displaystyle F_{v,\mathrm{Ed}} = 2.4 kN · Fv,Rd\displaystyle F_{v,\mathrm{Rd}} = 4 kN · Fax,Ed\displaystyle F_{ax,\mathrm{Ed}} = 3 kN · Fax,Rd\displaystyle F_{ax,\mathrm{Rd}} = 5 kN

η\displaystyle \eta = 0.72

Standard and source

Result
η\displaystyle \eta in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
η\displaystyle \eta = 0.72 1= ((2.4 kN) / (4 kN))² + ((3 kN) / (5 kN))²

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Timber.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.