Actions and loads · Thermal actions
Building internal summer temperature Tin
Internal temperature of a building in summer derived from external shade air temperature Tout,max and offset δT,1 (in °C): Tin = Tout,max - δT,1.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Maximum external shade air temperature (in °C) | 1 | ||
| Internal summer temperature reduction (in K) | 1 | ||
| Building internal summer temperature (in °C) | 1 | Result |
Worked example
= 35 · = 10
= 25 1
Standard and source
- Standard
- EN 1991-1-5:2003
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.