Critical steel temperature Θa,cr (EN 1993-1-2)
Critical temperature of carbon steel structural members as a function of degree of utilization μ0 (>= 0.013) according to EN 1993-1-2 Clause 4.2.4 Eq. (4.22): Θacr = 39.19 · ln(1 / (0.9674 · μ0³.833) - 1) + 482.
- EN 1993-1-2:2005
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Degree of utilization at time t = 0 (0.013 to 0.99) | 1 | ||
| Critical steel temperature (in °C) | 1 | Result |
Worked example
= 0.5 1
= 584.99 1
Standard and source
- Standard
- EN 1993-1-2:2005
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.