Design · Steel

Design plastic tension resistance of cross-section Npl,Rd

  • Type: Resistance
  • Version 1
  • reviewed on 11/9/2026

Design plastic tension resistance of the gross cross-section: Npl,Rd = A · fy / γM0.

Npl,Rd=A⋅fyγM0\displaystyle N_{\mathrm{pl},\mathrm{Rd}} = \frac{A \cdot f_{y}}{\gamma_{\mathrm{M0}}}

Call in Calculate moden_pl_rd_ec3(A; f_y; gamma_M0)

Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
A\displaystyle ACross-sectional aream²
fy\displaystyle f_{y}Yield strengthN/mm²
γM0\displaystyle \gamma_{\mathrm{M0}}Partial factor for cross-section resistance–
Npl,Rd\displaystyle N_{\mathrm{pl},\mathrm{Rd}}Design plastic tension resistancekNResult

Worked example

A\displaystyle A = 0.005383 m² · fy\displaystyle f_{y} = 235 N/mm² · γM0\displaystyle \gamma_{\mathrm{M0}} = 1

Npl,Rd\displaystyle N_{\mathrm{pl},\mathrm{Rd}} = 1,265.01 kN · Source: EN 1993-1-1:2005 Eq. (6.6)

Scope and standard

Tension members without fastener holes or with holes designed for net section check.

Standard
EN 1993-1-1:2005, clause 6.2.3 (2), Eq. (6.6)
Result
Npl,Rd\displaystyle N_{\mathrm{pl},\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Npl,Rd\displaystyle N_{\mathrm{pl},\mathrm{Rd}} = 1,265.01 kN= (0.005383 m²) · (235 N/mm²) / 1

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Steel.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.