Actions and loads · Snow loads

Snow load shape coefficient for cylindrical curved roofs

  • Type: Coefficient
  • Version 1
  • reviewed on 11/10/2026

Snow load shape coefficient μ3 for cylindrical barrel roofs based on sag ratio h/b according to EN 1991-1-3 Clause 5.3.5.

μ3=0.2+10⋅(h/b)\displaystyle \mu _{3} = 0.2 + 10 \cdot (h / b)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

μ3

Formula and quantities

SymbolNameUnitNote
h\displaystyle hRise of the arch/curvem
b\displaystyle bSpan of the roofm
μ3\displaystyle \mu_{3}Cylindrical roof snow shape coefficient–Result

Worked example

h\displaystyle h = 2 m · b\displaystyle b = 25 m

μ3\displaystyle \mu_{3} = 1

Standard and source

Standard
EN 1991-1-3:2003, clause 5.3.5
Result
μ3\displaystyle \mu_{3} (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
μ3\displaystyle \mu_{3} = 1= 0.2 + 10 · ((2 m) / (25 m))