Actions and loads · Snow loads

Snow load on a roof

  • Type: Action
  • Version 1
  • reviewed on 11/6/2026

Snow load on a roof for persistent and transient design situations: the characteristic ground snow load multiplied by the roof shape coefficient, the exposure coefficient and the thermal coefficient.

s=μi⋅Ce⋅Ct⋅sk\displaystyle s = μ_{i}·C_{e}·C_{t}·s_{k}

Call in Calculate modes_roof_ec1(mu_i; C_e; C_t; s_k)

Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

ssk

Formula and quantities

SymbolNameUnitNote
μi\displaystyle μ_{i}Snow load shape coefficient–
Ce\displaystyle C_{e}Exposure coefficient–
Ct\displaystyle C_{t}Thermal coefficient–
sk\displaystyle s_{k}Characteristic ground snow loadkN/m²From the national annex for the site and altitude.
s\displaystyle sSnow load on the roofkN/m²Result

Worked example

μi\displaystyle μ_{i} = 0.8 · Ce\displaystyle C_{e} = 1 · Ct\displaystyle C_{t} = 1 · sk\displaystyle s_{k} = 0.85 kN/m²

s\displaystyle s = 0.68 kN/m² · Source: hand calculation

Scope and standard

Persistent and transient design situations.

Standard
EN 1991-1-3:2003, clause 5.2(3), Eq. (5.1)
Result
s\displaystyle s in kN/m²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
s\displaystyle s = 0.68 kN/m²= 0.8 · 1 · 1 · (0.85 kN/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Actions and loads › Snow loads.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.