Actions and loads · Seismic actions

Lower bound of horizontal design response spectrum Sd,min (EN 1998-1)

  • Type: Action
  • Version 1
  • reviewed on 11/24/2026

Minimum lower-bound value of the horizontal design response spectrum according to EN 1998-1 Clause 3.2.2.5 Eq. (3.16): Sdmin = β · ag.

Sd,min=β⋅ag\displaystyle S_{\mathrm{d},\mathrm{min}} = \beta \cdot a_{g}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Sdmin

Formula and quantities

SymbolNameUnitNote
β\displaystyle \betaLower bound factor for horizontal design spectrum (recommended 0.2)1
ag\displaystyle a_{g}Design ground acceleration on Type A groundm/s²
Sdmin\displaystyle S_{dmin}Lower bound horizontal design spectral accelerationm/s²Result

Worked example

β\displaystyle \beta = 0.2 1 · ag\displaystyle a_{g} = 2.5 m/s²

Sdmin\displaystyle S_{dmin} = 0.5 m/s²

Standard and source

Result
Sdmin\displaystyle S_{dmin} in m/s²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Sdmin\displaystyle S_{dmin} = 0.5 m/s²= (0.2 1) · (2.5 m/s²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Actions and loads › Seismic actions.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.