Actions and loads · Seismic actions
Strong-column weak-beam capacity design moment sum (EN 1998-1)
Minimum required sum of design flexural resistances of columns framing into a beam-column joint according to EN 1998-1 Clause 4.4.2.3 Eq. (4.29): MRcreq = 1.3 · MRbsum.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Sum of design flexural resistances of beams framing into joint | kNm | ||
| Minimum required sum of column flexural resistances | kNm | Result |
Worked example
= 400 kNm
= 520 kNm
Standard and source
- Standard
- EN 1998-1:2004
- Result
- in kNm
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my memberwith Mia in CALC
- Compare with RFEM/RSTAB resultshand calculation versus model
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Actions and loads › Seismic actions.
Miaknows the formula catalog and asks for what is missing.