Design · Masonry
Characteristic shear strength of masonry
Characteristic shear strength of masonry with filled head joints: fvk = min(fvk0 + 0.4 · σd, fvk,lim).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Characteristic initial shear strength | N/mm² | ≥ 0 | |
| Design compressive stress perpendicular to shear | N/mm² | ≥ 0 | |
| Upper limit of characteristic shear strength | N/mm² | > 0 | |
| Characteristic shear strength of masonry | N/mm² | Result |
Worked examples
Below upper limit
= 0.2 N/mm² · = 0.8 N/mm² · = 1 N/mm²
= 0.52 N/mm² · Source: hand calculation
Capped by upper limit
= 0.2 N/mm² · = 2.5 N/mm² · = 1 N/mm²
= 1 N/mm² · Source: hand calculation
Scope and standard
Masonry under shear with vertical compressive stress according to EN 1996-1-1, clause 3.6.2.
- Standard
- EN 1996-1-1-2005-a1:2012, clause 3.6.2, Eq. (3.5)
- Result
- in N/mm²
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my dimensionsenter values, check the result
- Compare with a catalog sectionformula value and table value
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Masonry.
Miaknows the formula catalog and asks for what is missing.