Design · Masonry

Characteristic shear strength of masonry

  • Type: Property
  • Version 1
  • reviewed on 11/13/2026

Characteristic shear strength of masonry with filled head joints: fvk = min(fvk0 + 0.4 · σd, fvk,lim).

fvk=min⁡(fvk0+0.4⋅σd, fvk,lim⁡)\displaystyle f_{vk} = \min\left(f_{vk0} + 0.4 \cdot \sigma_{\mathrm{d}},\, f_{vk,\lim}\right)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fvkσd

Formula and quantities

SymbolNameUnitNote
fvk0\displaystyle f_{vk0}Characteristic initial shear strengthN/mm²fvk0\displaystyle f_{vk0} ≥ 0
σd\displaystyle σ_{\mathrm{d}}Design compressive stress perpendicular to shearN/mm²σd\displaystyle σ_{\mathrm{d}} ≥ 0
fvk,lim\displaystyle f_{vk,\mathrm{lim}}Upper limit of characteristic shear strengthN/mm²fvk,lim\displaystyle f_{vk,\mathrm{lim}} > 0
fvk\displaystyle f_{vk}Characteristic shear strength of masonryN/mm²Result

Worked examples

Below upper limit

fvk0\displaystyle f_{vk0} = 0.2 N/mm² · σd\displaystyle σ_{\mathrm{d}} = 0.8 N/mm² · fvk,lim\displaystyle f_{vk,\mathrm{lim}} = 1 N/mm²

fvk\displaystyle f_{vk} = 0.52 N/mm² · Source: hand calculation

Capped by upper limit

fvk0\displaystyle f_{vk0} = 0.2 N/mm² · σd\displaystyle σ_{\mathrm{d}} = 2.5 N/mm² · fvk,lim\displaystyle f_{vk,\mathrm{lim}} = 1 N/mm²

fvk\displaystyle f_{vk} = 1 N/mm² · Source: hand calculation

Scope and standard

Masonry under shear with vertical compressive stress according to EN 1996-1-1, clause 3.6.2.

Standard
EN 1996-1-1-2005-a1:2012, clause 3.6.2, Eq. (3.5)
Result
fvk\displaystyle f_{vk} in N/mm²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fvk\displaystyle f_{vk} = 0.52 N/mm²= min((0.2 N/mm²) + 0.4 · (0.8 N/mm²); (1 N/mm²))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Masonry.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.