Total IGU isochoric cavity pressure p0 (EN 16612)
Total isochoric pressure in an insulating glass unit combining temperature change, meteorological barometric pressure change, and altitude difference according to EN 16612 Clause 7.3.3: p0 = cT · ΔT - Δpmet + cH · ΔH.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Temperature isochoric pressure coefficient (kPa/K, typically 0.34) | N/m² | ||
| Cavity gas temperature change (in K) | 1 | ||
| Meteorological barometric pressure change | N/m² | ||
| Altitude isochoric pressure coefficient (typically 0.012 kPa/m) | N/m³ | ||
| Altitude difference between site and production | m | ||
| Total isochoric pressure | N/m² | Result |
Worked example
= 340 N/m² · = 20 · = -2,000 N/m² · = 12 N/m³ · = 300 m
= 12,400 N/m²
Standard and source
- Standard
- EN 16612:2019
- Result
- in kPa