Geotechnics · Earth pressure

Uplift limit state verification ratio (UPL)

  • Type: Verification
  • Version 1
  • reviewed on 11/12/2026

Verification against failure by uplift (UPL): ηUPL = Vdstd / (Gstbd + Rd) <= 1.0.

ηUPL=Vdst,dGstb,d+Rd\displaystyle \eta_\mathrm{UPL} = \frac{V_{dst,\mathrm{d}}}{G_{stb,\mathrm{d}} + R_{\mathrm{d}}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
Vdst,d\displaystyle V_{dst,\mathrm{d}}Design destabilising vertical pore water uplift forcekN
Gstb,d\displaystyle G_{stb,\mathrm{d}}Design stabilising permanent vertical load (dead weight)kN
Rd\displaystyle R_{\mathrm{d}}Design tensile/frictional resistance against upliftkN
ηUPL\displaystyle \eta_\mathrm{UPL}Uplift verification ratio–Result

Worked example

Vdst,d\displaystyle V_{dst,\mathrm{d}} = 800 kN · Gstb,d\displaystyle G_{stb,\mathrm{d}} = 700 kN · Rd\displaystyle R_{\mathrm{d}} = 300 kN

ηUPL\displaystyle \eta_\mathrm{UPL} = 0.8 · Source: EN 1997-1:2004 clause 2.4.7.4

Scope and standard

Uplift limit state (UPL) verification of buried structures according to EN 1997-1 Clause 2.4.7.4.

Standard
EN 1997-1:2004, clause 2.4.7.4, Eq. (2.8)
Result
ηUPL\displaystyle \eta_\mathrm{UPL} (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ηUPL\displaystyle \eta_\mathrm{UPL} = 0.8= (800 kN) / ((700 kN) + (300 kN))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Geotechnics › Earth pressure.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.