Geotechnics · Earth pressure

Maximum trapezoidal base contact pressure (EN 1997-1)

  • Type: Action
  • Version 1
  • reviewed on 11/24/2026

Maximum edge contact pressure under a strip foundation or retaining wall base with eccentricity e <= B / 6 (no uplift) according to EN 1997-1 Clause 6.5: σmax = (Vd / B) · (1 + (6 · e) / B).

σmax=VdB⋅(1+6eB)\displaystyle \sigma_{\mathrm{max}} = \frac{V_{\mathrm{d}}}{B} \cdot \left(1 + \frac{6 e}{B}\right)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

VdB

Formula and quantities

SymbolNameUnitNote
Vd\displaystyle V_{\mathrm{d}}Design vertical load per unit wall lengthkN/m
B\displaystyle BFoundation base widthm
e\displaystyle eLoad eccentricity (e <= B/6)m
σmax\displaystyle \sigma_{\mathrm{max}}Maximum edge contact pressureN/m²Result

Worked example

Vd\displaystyle V_{\mathrm{d}} = 240 kN/m · B\displaystyle B = 2.4 m · e\displaystyle e = 0.3 m

σmax\displaystyle \sigma_{\mathrm{max}} = 175,000 N/m²

Standard and source

Result
σmax\displaystyle \sigma_{\mathrm{max}} in kPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
σmax\displaystyle \sigma_{\mathrm{max}} = 175,000 N/m²= ((240 kN/m) / (2.4 m)) · (1 + (6 · (0.3 m)) / (2.4 m))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Geotechnics › Earth pressure.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.