Geotechnics · Bearing resistance
Load inclination factor ic (drained cohesion)
Load inclination factor ic for drained conditions: ic = iq - (1 - iq) / (Nc · tan(phi')).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Load inclination factor i_q | – | ||
| Bearing capacity factor N_c | – | ||
| Effective friction angle of soil | ° | ||
| Load inclination factor i_c | – | Result |
Worked example
= 0.85 · = 30.14 · = 30 °
= 0.84138 · Source: EN 1997-1:2004 Annex D
Scope and standard
Bearing resistance of shallow foundations under drained conditions according to EN 1997-1 Annex D.
- Standard
- EN 1997-1:2004, clause D.4, Eq. (D.3)
- Result
- (dimensionless)
Reference to clause and equation, no standard text. The description is written in our own words.