Geotechnics · Bearing resistance

Effective foundation width B'

  • Type: Property
  • Version 1
  • reviewed on 11/10/2026

Effective foundation width taking eccentricity into account: B' = B - 2 · eB.

B′=B−2⋅eB\displaystyle B' = B - 2 \cdot e_{\mathrm{B}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

eBBB'

Formula and quantities

SymbolNameUnitNote
B\displaystyle BFoundation widthm
eB\displaystyle e_{\mathrm{B}}Load eccentricity in width directionm
B′\displaystyle B'Effective foundation widthmResult

Worked example

B\displaystyle B = 2.5 m · eB\displaystyle e_{\mathrm{B}} = 0.25 m

B′\displaystyle B' = 2 m · Source: EN 1997-1:2004 Eq. (6.1)

Scope and standard

Shallow foundations under eccentric loading according to EN 1997-1, clause 6.5.2.2.

Standard
EN 1997-1:2004, clause 6.5.2.2 (1), Eq. (6.1)
Result
B′\displaystyle B' in m

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
B′\displaystyle B' = 2 m= (2.5 m) - 2 · (0.25 m)