Actions and loads · Combinations of actions
ULS equilibrium combination (EQU)
Design effect of actions for static equilibrium (EQU) with unfavourable and favourable permanent actions and one leading variable action according to EN 1990 Eq. 6.10: Ed = γGsup · Gksup + γGinf · Gkinf + γQ · Qk1.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Unfavourable permanent partial factor | 1 | ||
| Unfavourable permanent action | kN | ||
| Favourable permanent partial factor | 1 | ||
| Favourable permanent action | kN | ||
| Variable action partial factor | 1 | ||
| Leading variable action | kN | ||
| Design effect of actions | kN | Result |
Worked example
= 1.1 1 · = 100 kN · = 0.9 1 · = -40 kN · = 1.5 1 · = 30 kN
= 119 kN
Standard and source
- Standard
- EN 1990:2002
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Clarify values for my siteaccording to the national annex
- Calculate for my memberwith Mia in CALC
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Actions and loads › Combinations of actions.
Miaknows the formula catalog and asks for what is missing.