Reduction factor kl for headed shear studs welded in ribs of profiled steel sheeting running parallel to the supporting beam according to EN 1994-1-1 Clause 6.6.4.1 Eq. (6.22): kl = 0.6 · (b0 / hp) · (hsc / hp - 1).

kl=0.6⋅(b0/hp)⋅(hsc/hp−1)\displaystyle k_{l} = 0.6 \cdot (b_{0} / h_{p}) \cdot (h_{sc} / h_{p} - 1)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

b0hpkl

Formula and quantities

SymbolNameUnitNote
b0\displaystyle b_{0}Mean width of concrete ribmm
hp\displaystyle h_{p}Overall depth of profiled steel sheetingmm
hsc\displaystyle h_{sc}Overall nominal height of headed studmm
kl\displaystyle k_{l}Parallel sheeting reduction factor (<= 1.0)1Result

Worked examples

60 mm deck, 110 mm stud

b0\displaystyle b_{0} = 100 mm · hp\displaystyle h_{p} = 60 mm · hsc\displaystyle h_{sc} = 110 mm

kl\displaystyle k_{l} = 0.833333

80 mm deck, 125 mm stud

b0\displaystyle b_{0} = 120 mm · hp\displaystyle h_{p} = 80 mm · hsc\displaystyle h_{sc} = 125 mm

kl\displaystyle k_{l} = 0.50625

Standard and source

Standard
EN 1994-1-1:2004, clause 6.6.4.1, Eq. (6.22)
Result
kl\displaystyle k_{l} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
kl\displaystyle k_{l} = 0.833333 1= 0.6 · ((100 mm) / (60 mm)) · ((110 mm) / (60 mm) - 1)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Composite.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.