Design · Composite
Stud reduction factor kl for parallel profiled sheeting (EN 1994-1-1)
Reduction factor kl for headed shear studs welded in ribs of profiled steel sheeting running parallel to the supporting beam according to EN 1994-1-1 Clause 6.6.4.1 Eq. (6.22): kl = 0.6 · (b0 / hp) · (hsc / hp - 1).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Mean width of concrete rib | mm | ||
| Overall depth of profiled steel sheeting | mm | ||
| Overall nominal height of headed stud | mm | ||
| Parallel sheeting reduction factor (<= 1.0) | 1 | Result |
Worked examples
60 mm deck, 110 mm stud
= 100 mm · = 60 mm · = 110 mm
= 0.833333
80 mm deck, 125 mm stud
= 120 mm · = 80 mm · = 125 mm
= 0.50625
Standard and source
- Standard
- EN 1994-1-1:2004, clause 6.6.4.1, Eq. (6.22)
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my dimensionsenter values, check the result
- Compare with a catalog sectionformula value and table value
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Composite.
Miaknows the formula catalog and asks for what is missing.