Design · Connections

Anchor steel shear resistance without lever arm VRk,s0 (EN 1992-4)

  • Type: Property
  • Version 1
  • reviewed on 11/25/2026

Characteristic steel shear failure resistance of a single fastener without lever arm according to EN 1992-4 Clause 7.2.2.3.1 Eq. (7.34): VRk,s0 = k6 · As · fuk.

VRk,s0=k6⋅As⋅fuk\displaystyle V_{Rk,s0} = k_{6} \cdot A_{s} \cdot f_{uk}
  • EN 1992-4:2018
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

VRks0Asfuk

Formula and quantities

SymbolNameUnitNote
k6\displaystyle k_{6}Steel shear factor (0.5 for f_uk > 800 MPa, 0.6 for ductile <= 800 MPa)1
As\displaystyle A_{s}Stressed cross-sectional area of anchormm²
fuk\displaystyle f_{uk}Characteristic steel ultimate tensile strengthN/m²
VRk,s0\displaystyle V_{Rk,s0}Characteristic steel shear resistancekNResult

Worked example

k6\displaystyle k_{6} = 0.5 · As\displaystyle A_{s} = 157 mm² · fuk\displaystyle f_{uk} = 800,000,000 N/m²

VRk,s0\displaystyle V_{Rk,s0} = 62.8 kN

Standard and source

Standard
EN 1992-4:2018
Result
VRk,s0\displaystyle V_{Rk,s0} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
VRk,s0\displaystyle V_{Rk,s0} = 62.8 kN= (0.5 1) · (157 mm²) · (800,000,000 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Connections.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.