Design · Aluminium
Bolt design shear resistance Fv,Rd
Design shear resistance per shear plane of a bolt in an aluminium connection: Fv,Rd = αv · fub · A / γM2.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Shear plane factor (0.6 or 0.5 depending on bolt class and thread) | 1 | ||
| Ultimate tensile strength of bolt | N/m² | ||
| Relevant bolt cross-sectional area (A or A_s) | mm² | ||
| Partial factor for bolted connections | 1 | ||
| Design shear resistance per shear plane | kN | Result |
Worked example
= 0.6 · = 800,000,000 N/m² · = 157 mm² · = 1.25
= 60.29 kN
Standard and source
- Standard
- EN 1999-1-1:2007
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.