Actions and loads · Accidental actions

Vertical tying force for columns and walls

  • Type: Action
  • Version 1
  • reviewed on 11/14/2026

Minimum vertical tie force Tv equal to the largest design vertical permanent and variable load from any one storey on tributary area At: Tv = (gk + ψ · qk) · At.

Tv=(gk+ψ⋅qk)⋅At\displaystyle T_{v} = (g_{k} + \psi \cdot q_{k}) \cdot A_{t}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
gk\displaystyle g_{k}Characteristic permanent surface loadN/m²
ψ\displaystyle \psiCombination factor for accidental design situation1
qk\displaystyle q_{k}Characteristic imposed surface loadN/m²
At\displaystyle A_{t}Tributary floor aream²
Tv\displaystyle T_{v}Vertical tying forcekNResult

Worked example

gk\displaystyle g_{k} = 6,000 N/m² · ψ\displaystyle \psi = 0.5 · qk\displaystyle q_{k} = 3,000 N/m² · At\displaystyle A_{t} = 36 m²

Tv\displaystyle T_{v} = 270 kN

Standard and source

Result
Tv\displaystyle T_{v} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Tv\displaystyle T_{v} = 270 kN= ((6,000 N/m²) + (0.5 1) · (3,000 N/m²)) · (36 m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Actions and loads › Accidental actions.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.