Actions and loads · Accidental actions
Peripheral horizontal tying force for structural integrity
Peripheral horizontal ring tie tensile force Tp = 0.4 · (gk + ψ · qk) · s · L to secure building perimeter according to EN 1991-1-7 Annex A.4 Eq. (A.2).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Characteristic dead weight | kN/m² | ||
| Combination factor | – | ||
| Characteristic imposed load | kN/m² | ||
| Spacing of perimeter ties/columns | m | ||
| Span of the floor bay | m | ||
| Perimeter tying force | kN | Result |
Worked example
= 5 kN/m² · = 0.5 · = 3 kN/m² · = 6 m · = 8 m
= 124.8 kN
Standard and source
- Standard
- EN 1991-1-7:2006, clause Annex A.4
- Result
- in kN