垂直于纹理受压的有效接触面积 Aef
垂直于纹理的有效接触面积:Aef = b · lef。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 构件宽度 | m | ||
| 有效接触长度 | m | ||
| 有效接触面积 | m² | Result |
实例
= 0.12 m · = 0.16 m
= 0.0192 m² · Source: EN 1995-1-1:2004 式 (6.3)
Scope and standard
根据EN 1995-1-1第6.1.5条的承压与支座设计。
- Standard
- EN 1995-1-1:2004,第6.1.5 (1)条,式(6.3)
- Result
- in m²
Reference to clause and equation, no standard text. The description is written in our own words.