荷载与作用 · 温度作用
壁厚方向自平衡热应力 σT,wall
受约束板或圆柱壳壁在贯穿壁厚线性温差 δT,M 下的最大弹性表面应力:σT,wall = E · αT · δT,M / (2 · (1 - ν))。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 壁材弹性模量 | N/m² | ||
| 线性热膨胀系数(1/K) | 1 | ||
| 穿壁温差(K) | 1 | ||
| 壁材泊松比 | 1 | ||
| 壁表面热应力 | N/m² | Result |
实例
= 33,000,000,000 N/m² · = 1e-5 · = 30 · = 0.2
= 6,190,000 N/m²
Standard and source
- Standard
- EN 1991-1-5:2003
- Result
- in MPa
Reference to clause and equation, no standard text. The description is written in our own words.