设计 · 玻璃
对边支承玻璃板挠度 (EN 16612)
根据 EN 16612 第 7.1 条均布面荷载下对边简支玻璃板的跨中最大挠度:w = (5 · (1 - ν²) · q · L⁴) / (32 · E · h³)。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 玻璃泊松比(通常取 0.23) | 1 | ||
| 均布面荷载 | N/m² | ||
| 支承边之间的跨度 | m | ||
| 玻璃弹性模量(通常为 70000 MPa) | N/m² | ||
| 玻璃板厚度 | m | ||
| 最大玻璃板挠度 | m | Result |
实例
= 0.23 · = 1,500 N/m² · = 1.2 m · = 70,000,000,000 N/m² · = 0.01 m
= 0.00657558 m
Standard and source
- Standard
- EN 16612:2019
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
检索将在 设计 › 玻璃 开始。
Miaknows the formula catalog and asks for what is missing.