设计 · 混凝土
考虑徐变的有效弹性模量 Ec,eff
考虑徐变影响的混凝土有效弹性模量,按 EN 1992-1-1 式 (5.26): Ec,eff = Ecm / (1 + φef)。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 混凝土割线弹性模量 | N/m² | ||
| 有效徐变比 | 1 | ||
| 混凝土有效弹性模量 | N/m² | Result |
实例
= 33,000,000,000 N/m² · = 2 1
= 11,000,000,000 N/m² · Source: EN 1992-1-1:2004 式 (5.26)
Scope and standard
按 EN 1992-1-1 的钢筋混凝土和预应力混凝土结构。
- Standard
- EN 1992-1-1:2004,第5.8.7.2 (1)条,式(5.26)
- Result
- in GPa
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
检索将在 设计 › 混凝土 开始。
Miaknows the formula catalog and asks for what is missing.