设计 · 混凝土
徐变修正系数 Kφ
名义曲率法中考虑徐变影响的系数,按 EN 1992-1-1 式 (5.37): Kφ = max(1.0; 1 + β · φef)。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 长细比参数 beta = 0.35 + f_ck/200 - lambda/150 | 1 | ||
| 有效徐变比 | 1 | ||
| 徐变修正系数 | 1 | Result |
实例
= 0.25 1 · = 1.6 1
= 1.4 1 · Source: EN 1992-1-1:2004 式 (5.37)
Scope and standard
符合EN 1992-1-1的细长钢筋混凝土柱。
- Standard
- EN 1992-1-1:2004,第5.8.8.3 (4)条,式(5.37)
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.