하중 및 작용 · 풍하중

MWFRS 설계풍압 (ASCE 7)

  • 유형: 하중
  • 버전 1
  • 2026. 11. 15.에 검토됨

ASCE/SEI 7-22 식 27.3-1에 따른 밀폐형 또는 부분밀폐형 강체 건물의 주풍력저항시스템(MWFRS) 설계풍압: p = q · G · Cp - qi · GCpi.

p=q⋅G⋅Cp−qi⋅(GCpi)\displaystyle p = q \cdot G \cdot C_{p} - q_{i} \cdot (GC_{pi})
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

qpCp

Formula and quantities

SymbolNameUnitNote
q\displaystyle q외부 속도압N/m²
G\displaystyle G돌풍영향계수1
Cp\displaystyle C_{p}외부 압력 계수1
qi\displaystyle q_{i}내부 속도압N/m²
GCπ\displaystyle GC_\pi 내부 압력계수 곱1
p\displaystyle p설계풍압N/m²Result

예제

q\displaystyle q = 1,200 N/m² · G\displaystyle G = 0.85 1 · Cp\displaystyle C_{p} = 0.8 1 · qi\displaystyle q_{i} = 1,200 N/m² · GCπ\displaystyle GC_\pi = -0.18 1

p\displaystyle p = 1,032 N/m²

Standard and source

Standard
ASCE 7-22
Result
p\displaystyle p in kPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
p\displaystyle p = 1,032 N/m²= (1,200 N/m²) · (0.85 1) · (0.8 1) - (1,200 N/m²) · (-0.18 1)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

하중 및 작용 › 풍하중에서 검색이 시작됩니다.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.