굽힘-전단 상호작용에 대한 전단 저감계수 ρ
VEd가 Vpl,Rd의 50%를 초과할 때 소성 모멘트 저항에 대한 저감계수 rho: ρ = (2 · VEd / Vpl,Rd - 1)².
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 설계 전단력 | kN | ||
| 설계 소성 전단 저항력 | kN | ||
| 전단 저감계수 | – | Result |
예제
= 280 kN · = 350 kN
= 0.36 · Source: EN 1993-1-1:2005 식 (6.29)
Scope and standard
V_Ed > 0.5 * V_pl,Rd인 굽힘-전단 조합 부재 (EN 1993-1-1 6.2.8).
- Standard
- EN 1993-1-1:2005, 6.2.8 (5) 절, 식 (6.29)
- Result
- (dimensionless)
Reference to clause and equation, no standard text. The description is written in our own words.