설계 · 유리

온도변화에 의한 복층유리 등적압력 p0,T (EN 16612)

  • 유형: 성질
  • 버전 1
  • 2026. 11. 25.에 검토됨

EN 16612 제7.3.3절에 따라 제조 조건 대비 온도차로 발생하는 등적 중공층 압력: p0T = cT · ΔT.

p0T=cT⋅ΔT\displaystyle p_{0T} = c_{T} \cdot \Delta T
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

p0T

Formula and quantities

SymbolNameUnitNote
cT\displaystyle c_{T}온도 등적압력 계수 (kPa/K, 일반적으로 0.34)N/m²
ΔT\displaystyle \Delta T중공층 기체 온도변화 (K)1
p0T\displaystyle p_{0T}온도 유발 등적압력N/m²Result

예제

cT\displaystyle c_{T} = 340 N/m² · ΔT\displaystyle \Delta T = 20

p0T\displaystyle p_{0T} = 6,800 N/m²

Standard and source

Result
p0T\displaystyle p_{0T} in kPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
p0T\displaystyle p_{0T} = 6,800 N/m²= (340 N/m²) · (20 1)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

설계 › 유리에서 검색이 시작됩니다.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.