설계 · 유리
복층유리판 내부 기후하중 pint (EN 16612)
EN 16612 제7.3.3절에 따라 등적압력으로 인해 이중 복층유리 각 유리판에 내·외측으로 작용하는 유효 내부압력 하중: pint = φIGU · p0.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 복층유리 계수 | 1 | ||
| 총 등적압력 | N/m² | ||
| 유리판 내부 기후압력 하중 | N/m² | Result |
예제
= 0.35 · = 12,400 N/m²
= 4,340 N/m²
Standard and source
- Standard
- EN 16612:2019
- Result
- in kPa