설계 · 접합부
콘크리트 콘 기준 투영면적 Ac,N0 (EN 1992-4)
EN 1992-4 제7.2.1.4절 식 (7.3)에 따른 충분한 간격과 연단거리를 가진 단일 패스너의 기준 콘크리트 콘 투영면적: AcN0 = (3 · hef)².
- EN 1992-4:2018
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 패스너의 유효매입깊이 | mm | ||
| 기준 콘 투영면적 | mm² | Result |
예제
= 100 mm
= 90,000 mm²
Standard and source
- Standard
- EN 1992-4:2018
- Result
- in mm²
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
설계 › 접합부에서 검색이 시작됩니다.
Miaknows the formula catalog and asks for what is missing.