설계 · 알루미늄

전단력 활용률 ηV

  • 유형: 검토
  • 버전 1
  • 2026. 11. 13.에 검토됨

수직 전단력을 받는 알루미늄 단면의 검토: ηV = VEd / VRd.

ηV=VEd/VRd\displaystyle \eta _{V} = V_{\mathrm{Ed}} / V_{\mathrm{Rd}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

VEd+VRd-VRd

Formula and quantities

SymbolNameUnitNote
VEd\displaystyle V_{\mathrm{Ed}}설계 전단력kN
VRd\displaystyle V_{\mathrm{Rd}}설계 전단 저항력kN
ηV\displaystyle \eta_{V}전단 이용률1Result

예제

VEd\displaystyle V_{\mathrm{Ed}} = 95 kN · VRd\displaystyle V_{\mathrm{Rd}} = 163.75 kN

ηV\displaystyle \eta_{V} = 0.58

Standard and source

Result
ηV\displaystyle \eta_{V} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ηV\displaystyle \eta_{V} = 0.580153 1= (95 kN) / (163.75 kN)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

설계 › 알루미늄에서 검색이 시작됩니다.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.