설계 · 목재

연결재 이중전단 내력 Mode k Fv,Rk

  • 유형: 저항
  • 버전 1
  • 2026. 11. 10.에 검토됨

EN 1995-1-1 식 8.7k에 따른 이중전단 목재 접합부 Mode k의 전단면당 특성 내력: Fv,Rk = 1.15 · √(2 · β / (1 + β)) · √(2 · My,Rk · fh,1,k · d)

Fv,Rk=1.15⋅2⋅β/(1+β)⋅2⋅My,Rk⋅fh,1,k⋅d\displaystyle F_{v,Rk} = 1.15 \cdot \sqrt{2 \cdot \beta / (1 + \beta )} \cdot \sqrt{2 \cdot M_{y,Rk} \cdot f_{h,1,k} \cdot d}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

FvRkdfh1kMyRk

Formula and quantities

SymbolNameUnitNote
β\displaystyle \beta지압강도 비율1
My,Rk\displaystyle M_{y,Rk}연결재 항복 모멘트kNm
fh,1,k\displaystyle f_{h,1,k}측부재 지압강도N/m²
d\displaystyle d연결재 직경mm
Fv,Rk\displaystyle F_{v,Rk}Mode k 특성 내력kNResult

예제

β\displaystyle \beta = 1 · My,Rk\displaystyle M_{y,Rk} = 0.32 kNm · fh,1,k\displaystyle f_{h,1,k} = 24,000,000 N/m² · d\displaystyle d = 16 mm

Fv,Rk\displaystyle F_{v,Rk} = 18.01 kN

Standard and source

Result
Fv,Rk\displaystyle F_{v,Rk} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Fv,Rk\displaystyle F_{v,Rk} = 18.0282 kN= 1.15 · sqrt(2 · (1 1) / (1 + (1 1))) · sqrt(2 · (0.32 kNm) · (24,000,000 N/m²) · (16 mm))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

설계 › 목재에서 검색이 시작됩니다.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.