설계 · 목재

목재보 유효 전단 폭 bef

  • 유형: 성질
  • 버전 1
  • 2026. 11. 9.에 검토됨

균열 영향을 고려한 목재보의 유효 폭: bef = kcr · b

bef=kcr⋅b\displaystyle b_{\mathrm{ef}} = k_{\mathrm{cr}} \cdot b
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
kcr\displaystyle k_{\mathrm{cr}}전단 저항 균열 계수–
b\displaystyle b단면 폭mm
bef\displaystyle b_{\mathrm{ef}}전단 유효 폭mmResult

예제

kcr\displaystyle k_{\mathrm{cr}} = 0.67 · b\displaystyle b = 140 mm

bef\displaystyle b_{\mathrm{ef}} = 93.8 mm · Source: EN 1995-1-1:2004 식 (6.13a)

Scope and standard

EN 1995-1-1 6.1.7절에 따른 목재 부재 전단 설계

Standard
EN 1995-1-1:2004, 6.1.7 (2) 절, 식 (6.13a)
Result
bef\displaystyle b_{\mathrm{ef}} in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
bef\displaystyle b_{\mathrm{ef}} = 93.8 mm= 0.67 · (140 mm)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

설계 › 목재에서 검색이 시작됩니다.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.