설계 · 강재

내부 판요소의 판좌굴 저감계수 ρ (EN 1993-1-5)

  • 유형: 성질
  • 버전 1
  • 2026. 11. 24.에 검토됨

EN 1993-1-5 제4.4(2)절에 따른 내부 압축판 요소(λp > 0.5 + √(0.085 - 0.055 · ψ))의 윈터 판좌굴 저감계수 rho: ρ = (λp - 0.055 · (3 + ψ)) / λp².

ρ=(λp−0.055⋅(3+ψ))/λp2\displaystyle \rho = (\lambda _{p} - 0.055 \cdot (3 + \psi )) / \lambda _{p}^2
  • EN 1993-1-5:2006
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

ψ

Formula and quantities

SymbolNameUnitNote
λp\displaystyle \lambda_{p}판 상대세장비1
ψ\displaystyle \psi연단응력비 sigma_2 / sigma_11
ρ\displaystyle \rho판좌굴 저감계수1Result

예제

λp\displaystyle \lambda_{p} = 1.2 · ψ\displaystyle \psi = 1

ρ\displaystyle \rho = 0.680556

Standard and source

Standard
EN 1993-1-5:2006
Result
ρ\displaystyle \rho in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

ρ\displaystyle \rho = 0.680556 1= ((1.2 1) - 0.055 · (3 + (1 1))) / (1.2 1)²

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

설계 › 강재에서 검색이 시작됩니다.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.