설계 · 유리

복층유리판 내부 기후하중 pint (EN 16612)

  • 유형: 성질
  • 버전 1
  • 2026. 11. 25.에 검토됨

EN 16612 제7.3.3절에 따라 등적압력으로 인해 이중 복층유리 각 유리판에 내·외측으로 작용하는 유효 내부압력 하중: pint = φIGU · p0.

pint=ϕIGU⋅p0\displaystyle p_{int} = \phi _{IGU} \cdot p_{0}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

pint

Formula and quantities

SymbolNameUnitNote
ϕIGU\displaystyle \phi_{IGU}복층유리 계수1
p0\displaystyle p_{0}총 등적압력N/m²
pint\displaystyle p_{int}유리판 내부 기후압력 하중N/m²Result

예제

ϕIGU\displaystyle \phi_{IGU} = 0.35 · p0\displaystyle p_{0} = 12,400 N/m²

pint\displaystyle p_{int} = 4,340 N/m²

Standard and source

Result
pint\displaystyle p_{int} in kPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
pint\displaystyle p_{int} = 4,340 N/m²= (0.35 1) · (12,400 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.