설계 · 콘크리트

콘크리트 파괴계수 fr (ACI 318)

  • 유형: 성질
  • 버전 1
  • 2026. 11. 15.에 검토됨

ACI 318-19 제19.2.3.1절(SI)에 따른 처짐 및 균열모멘트 계산용 콘크리트 파괴계수: fr = 0.62 · λ · √(fc / MPa) · MPa.

fr=0.62⋅λ⋅fc′\displaystyle f_{r} = 0.62 \cdot \lambda \cdot \sqrt{f'_{\mathrm{c}}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fc

Formula and quantities

SymbolNameUnitNote
λ\displaystyle \lambda경량콘크리트 보정계수 (보통콘크리트 1.0)1
fc\displaystyle f_{\mathrm{c}}콘크리트 설계기준압축강도N/m²
fr\displaystyle f_{r}파괴계수N/m²Result

예제

λ\displaystyle \lambda = 1 1 · fc\displaystyle f_{\mathrm{c}} = 28,000,000 N/m²

fr\displaystyle f_{r} = 3,280,700 N/m²

Standard and source

Standard
ACI 318-19
Result
fr\displaystyle f_{r} in MPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fr\displaystyle f_{r} = 3,280,730 N/m²= 0.62 · (1 1) · sqrt((28,000,000 N/m²) / [MPa]) · [MPa]

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

설계 › 콘크리트에서 검색이 시작됩니다.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.