지렛대 팔이 없는 앵커 강재 전단저항 VRk,s0 (EN 1992-4)
EN 1992-4 제7.2.2.3.1절 식 (7.34)에 따른 지렛대 팔이 없는 단일 앵커의 특성 강재 전단파괴저항: VRk,s0 = k6 · As · fuk.
- EN 1992-4:2018
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 강재 전단계수 (f_uk > 800 MPa일 때 0.5, 연성 <= 800 MPa일 때 0.6) | 1 | ||
| 앵커의 유효단면적 | mm² | ||
| 강재 특성 극한인장강도 | N/m² | ||
| 특성 강재 전단저항 | kN | Result |
예제
= 0.5 · = 157 mm² · = 800,000,000 N/m²
= 62.8 kN
Standard and source
- Standard
- EN 1992-4:2018
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.