EN 1995-1-1 6.1.2式(6.1)による繊維方向引張応力度比: η = σt,0,d / ft,0,d ≦ 1.0。

η=σt,0,d/ft,0,d\displaystyle \eta = \sigma _{t,0,\mathrm{d}} / f_{t,0,\mathrm{d}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Formula and quantities

SymbolNameUnitNote
σt,0,d\displaystyle \sigma_{t,0,\mathrm{d}}繊維方向引張設計応力度N/m²
ft,0,d\displaystyle f_{t,0,\mathrm{d}}繊維方向引張設計強度N/m²
η\displaystyle \eta引張応力度比1Result

例題

σt,0,d\displaystyle \sigma_{t,0,\mathrm{d}} = 8,500,000 N/m² · ft,0,d\displaystyle f_{t,0,\mathrm{d}} = 11,000,000 N/m²

η\displaystyle \eta = 0.7727

Standard and source

Result
η\displaystyle \eta in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
η\displaystyle \eta = 0.772727 1= (8,500,000 N/m²) / (11,000,000 N/m²)